Eaton Moeller® series LSM Safety position switch, LS(M)-…, Rounded plunger, Basic device, expandable, 1 N/O, 1 NC, EN 50047 Form B, Snap-action contact - Yes, Yellow, Metal, Cage Clamp, -25 - +70 °C
Product Name |
Eaton Moeller® series LSM Safety position switch
|
Catalog Number |
266140
|
Product Length/Depth |
33.5 mm
|
Product Height |
76.5 mm
|
Product Width |
31 mm
|
Product Weight |
0.147 kg
|
Compliances |
CE Marked
|
Certifications |
UL 508
EN 60947-5 IEC 60947-5 CSA Std. C22.2 No. 14 CSA Class No.: 3211-03 CSA File No.: 012528 CSA-C22.2 No. 14 IEC/EN 60947-5 UL Category Control No.: NKCR IEC/EN 60947 UL CE CSA UL File No.: E29184 |
Type |
Safety position switch
|
Features |
Forced opening
Positive opening Expandable Snap-action contact |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Cable entry metrical
|
Enclosure material finishing |
Other
|
Operating frequency |
6000 Operations/h
|
Pollution degree |
3
|
Actuator alignment |
Roller cam straight
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Enclosure material |
Metal
|
Enclosure type |
Cuboid
|
Rated operational current (Ie) at DC-13, 110 V |
0.6 A
|
Rated operational current (Ie) at DC-13, 125 V |
0.8 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.3 A
|
Rated operational current (Ie) at DC-13, 24 V |
3 A
|
Rated operational current for specified heat dissipation (In) |
6 A
|
Sensor height |
61 mm
|
Sensor length |
33.5 mm
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Width sensor |
31 mm
|
Product category |
Rounded plunger
|
Action |
2021118113756-Mechanical Limit Switches.xlsm-Data
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Enclosure color |
Yellow Cover
|
Actuating force at beginning/end of stroke |
1.0 N/8.0 N
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Actuator type |
Plunger
|
Actuating torque of rotary drives |
0.2 Nm
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Diameter sensor |
0 mm
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.17 W
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Number of safety auxiliary contacts |
0
|
Rated insulation voltage (Ui) |
400 V
|
Rated operational current (Ie) at AC-15, 125 V |
6 A
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
6 A
|
Rated operational current (Ie) at AC-15, 24 V |
6 A
|
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V |
4 A
|
Design |
EN 50047 Form B
|
Mounting position |
As required
|
Rated conditional short-circuit current (Iq) |
1 kA
|
Overvoltage category |
III
|
Control circuit reliability |
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA) |
Connection type |
Cage Clamp
|
Temperature resistance |
100 °C, Contact temperature of roller head
|
Degree of protection |
IP66/IP67
NEMA Other |
Interface type |
None
|
Switch function type |
Quick-break switch
|
Lifespan |
8,000,000 mechanical Operations
|
Repetition accuracy |
0.15 mm (Contacts/switching capacity)
|
Shock resistance |
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
|
Supply frequency |
Max. 400 Hz, Contacts
|
Suitable for |
Safety functions
|
Operating speed |
Max. 1/0.5 m/s (with DIN cam, mechanical actuation)
For angle of actuation α = 0°/30° |
Short-circuit protection rating |
Max. 6 A gG/gL, Fuse, Contacts
|
Terminal capacity (flexible with ferrule) |
1 x (0.5 - 1.5) mm²
|
Terminal capacity (solid) |
1 x (0.5 - 2.5) mm²
|